The IR-BA series is a non-contact and high-speed compact radiation thermometer. The card sized thermometer with built-in signal converting function of 4-20mA output can easily be installed in narrow places, production lines and small equipment.
A standard speed type and a high-speed type (50ms/95%) are respectively available in standard type and small-target/short-distance type and small-target/long-distance type, and special application types for glass, lamp-anneal, film, and burning gas.
|
High-speed response Standard: 100ms, High-speed: 50ms |
|
Compact & light-weight W32 x H56 x D100 mm, 220g |
| Signal conversion built-in |
| Emissivity setting by digital switch |
|
Peripheral units including: Indicator with power supply, converter with reflection correction, etc. |
|
CE Excluding special application types (IR-BAX) |
| General Type | ||||||
| IR-BAT1A | Standard | 0-300°C | 100ms | Φ40/500mm |
Less than 300°C: ±3°C 300°C or higher: ±1% of measured value (at ε = 1.0 and reference operating condition) |
8 to 14µm |
| IR-BAT1B | 0-600°C | |||||
| IR-BAT2A |
Small target/ Short distance |
0-300°C | Φ5/80mm | |||
| IR-BATSA | Small target/ | 0-300°C | Φ40/1000mm | |||
| IR-BATSB | Long distance | 0-600°C | ||||
| High-Speed Type | ||||||
| IR-BAT1M | Standard | 0-300°C | 50ms | Φ40/500mm |
Less than 300°C: ±3°C 300°C or higher: ±1% of measured value (at ε = 1.0 and reference operating condition) |
8 to 14µm |
| IR-BAT1P | 0-600°C | |||||
| IR-BAT2M |
Small target/ Short distance |
0-300°C | Φ5/80mm | |||
| IR-BATSM |
Small target/ Long distance |
0-300°C | Φ40/1000mm | |||
| IR-BATSP | 0-600°C | |||||
| Application Type | ||||||
| IR-BAXG1 | Glass | 100-400°C | 1s | Φ20/150mm | ±4°C | 4.6 to 5.2µm |
| IR-BAXL1 | Lamp anneal | 400-1300°C | 1s | Φ40/500mm | 1% | 3.43µm half-band width 120nm |
| IR-BAXF1 | Polyethylene | 80-250°C | 1s | Φ40/500mm | ±4°C | |
| IR-BAXF2 | Polyester | 50-150°C | 1s | Φ40/500mm | ±4°C | 7.6 to 8.4µm |
| IR-BAXH1 | Burning gas | 500-1300°C | 10s | Φ100/1000mm | 1.5% | 4.3µm |
| Measurement | Wide-band system (General type and high-speed type) |
| Narrow-band system (Special application type) | |
| Element | Thermopile |
| Resolution |
0.2°C (0-300°C) general type 0.5°C (0-600°C) high-speed type |
| Repeatability |
±0.2°C (0-300°C) general type ±0.3°C (0-600°C) high-speed type |
| Optics | Ge lens |
| Emissivity | 1.99 to 0.10 by digital switch |
| Analog output | 4 to 20mADC (Load: less than 280Ω) |
| Working temperature | 0 to 50°C |
| Power | 12 to 24VDC |
| Current consumption | 60mA or lower |
| Connecting cable | Standard 2m 5m for IR-BAXH1 |
| Casing | Diecast aluminum |
| Water proofing | JIS C-920 Drip-proof II, IP-X2 |
| Mounting | Fixing 2 x M4 screws or tripod |
| Weight | About 220g |
| CE |
EN61326 Class A, EN61326 Annex A Except special application types and extension cable type |
| Conditions for CE conformance |
1. An individual DC power unit for thermometer is required.(Recommended power unit: IR-ZFEP) 2. All of the thermometer, the connection cable, and a DC power unit should be used indoors. |
| Stability | ±10°C under the EMC test environment |