The IR-AH series is non-contact handheld type digital radiation thermometers for the measurement of temperature. The thermometers have features of a wide measuring range from -50°C to 3000°C, digital displays of the measured value in the finder and on the panel board, and storing function of the measured data. An RS-232C port is provided to transmit the measured data to a personal computer. With a Data Logging Software (sold separately) , you can analysis and manage the measured data.
|
Data storage Maximum 1000 data can be stored. The data stored are readable on the display with index numbers for easy classification of data. |
|
Easy-to-read internal and external digital display A measured value is digitally displayed in the finder and on the panel board. |
|
RS-232C port The communications interface port (RS-232C) is provided to transmit the measured data to a personal computer. |
|
Signal modulation Measurement modes of real value (real) maximum value (peak), average value (delay) and minimum value (valley) are selectable for measuring purposes. |
|
Data logging software The data logging software is separately prepared for the analysis and management of the measured data. |
|
Analog output (option) The analog output of 0 to 1VDC is offered at an optional specification. By using an AC power adapter (option), the continuous measurement enabled. |
|
Other functions Various functions including high/low alarms, °C/°F selection, auto-power-off, battery check and user's calibration (zero/span) are available. |
|
CE All models are complying with CE. |
| Model | Specification |
| IR-AHS | For medium/high temperature (Distance Factor 100) |
| IR-AHU | For high temperature (Distance Factor 250) |
| IR-AHT | For low temperature (Distance Factor 40) |
| Models | For medium/ high temp. IR-AHS |
For high temp. IR-AHU |
For low temp. IR-AHT |
| Measuring systems | Narrow band radiation thermometer | Wide band radiation thermometer | |
| Temperature ranges | 600 to 3000°C | 900 to 3000°C | -50 to 1000°C |
| Detectors | Silicon | Thermopile | |
| Spectral ranges | 0.96µm | 0.65µm | 8 to 13µm |
| Accuracy ratings | Lower than 1500°C: ±0.5% of reading ±1 digit< 1500 to 2000 °C: ±1% of reading ±1 digit More than 2000°C: ±2% of reading ±1 digit | Lower than 200°C: ±2°C ±1 digit More than 200°C: ±1% of reading ±1 digit | |
| Repeatability | 1°C±1 digit | ||
| Temperature drifts | 0.015% of reading/°C | Lower than 300°C: 0.15°C/°C 300 to 700°C: 0.05 of reading/°C More than 700°C: 0.025% of reading/°C | |
| Resolutions | 1°C | 1°C (more than 50°C) | |
| Response time | 0.5 second | 1 second | |
| Optical systems | Focusable lens type | Cassegrain forcusable mirror type | |
| Distance factors Measuring distance (L)/measuring diameter (D) | 100 | 250 | 40 |
| Measuring distance | 0.5m to∞ | 0.7m to ∞ | |
| Target sizes | Measuring distance/100(Φ, mm) | Measuring distance/250(Φ, mm) | Measuring distance/40(Φ, mm) |
| Collimation | Direct viewing finder | ||
| Lens diameters | Φ30mm | Φ40mm | |
| Display | LCD 4 digits display (in the finder and on the panel board) | ||
| Data storing function | Up to 1000 data | ||
| Emissivity | 0.10 to 1.00 (0.01 step) | ||
| Signal modulation | Real, Peak, Delay, Valley, Signal modulation ratio: 0 to 99 seconds, Peak hold, Valley hold, Hold after the measuring switch us turned off | ||
| Communications function | RS-232C (Data logging software: Sold separately) | ||
| Operating Temperature | 0 to 50°C | ||
| Power supply | Alkali AA (UM-3) battery 4 pieces (about 20 hours on continuous operation) | ||
| Casing material | ABS resin | ||
| Weights | About 700g | ||
| CE | EN61326+A1, Emission: Class B Immunity: Table 1 - minimum immunity requirement | ||