top

icon
img

KR3S SERIES Graphic Recorder

KR3S Series are network compatible advanced paperless Graphic
Recorder with high performance and high operating function along with
high visibility 10.4" TFT Color LCD touch-screen display.
 
Universal input with high speed of sampling rate 1sec. and high
accuracy rating of ±0.1% is realized. Measured data can be stored into
memory and USB and CF Card up to 8GB are supported. As it can be
monitored by a web browser, display on several computers on intranet
or internet. Not only that, FTP transfer of data file and E-mail
notification are also available.
 

 

Clear 10.4" TFT color LCD display. High visibility display with various

display functions. Real time/Historical trend screen, Bar-graph screen and numeric display are selectable for various applications.

 

Large capacity of data memory and various recording methods

USB slot and CF card is equipped as standard. 2GB of memory is provided and is expandable up to 8 GB. Various data storing methods are selectable such as schedule programming by time of day and time of date, recording start-up by external signal, and event and data logging of before and after trigger points for alarm.

 

Multi points stable recording with high speed/accuracy . High-speed

recording of approximately 1sec. for every point and high accuracy of ±0.1% are realized. Stable measuring and recording are possible with high speed. Withstand voltage between input channels is as high as 1000V AC (Excluding resistance thermometer input).

 

Easy operating and programming without manual With touch screen

display, operation and settings can be performed easily by touching buttons on the display.

 

Direct writing on the screen. With attached touch pen, various comments can be written on the screen.

 

Extend inputs with CHINO controllers. KR3S can communicate with up to 16 CHINO controllers for parameter settings and read/record of measuring values through low-order communications (Option).

 

USB port provided in front. Readout of data and files are possible by

connecting through an USB memory stick for PC.

 

Support LAN network (Option). Through Ethernet communications

(Option), various functions such as remote monitoring by a browser, and FTP server, and Email notification etc. are supported.

 

Analyzing/data acquisition application software (Optional)

It is easy to replay and edit the recorded data file with the software. 

Replay display has functions of vertical/horizontal trend, circular trend and also wave-analyzing and marking by using the cursor.

 

Models

Measuring Point

KR3S21-N0A-1NN

12 points / 1 Sec

KR3S41-N0A-1NN

24 points / 1 Sec

KR3S61-N0A-1NN

36 points / 1 Sec

KR3S81-N0A-1NN

48 points / 1 Sec

KR3S20-N0A-1NN

12 points / 0.1 Sec

KR3S40-N0A-1NN

24 points / 0.1 Sec

KR3S60N0A-1NN

36 points / 0.1 Sec

KR3S80-N0A-1NN

48 points / 0.1 Sec

 

 

INPUT SPECIFICATIONS

Measuring points: 12 points, 24 points, 36 points, 48 points

Input types:        Universal

DC voltage --- ±13.8mV, ±27.6mV, ±69.0mV

                         ±200mV, ±500mV, ±2V 

                         ±5V*, ±10V*, ±20V*, ±50V* 

                          (*with built-in voltage divider)

DC current --- With external shunt resistor (sold separately) 

Thermocouple --- B, R, S, K, E, J, T, N, PtRh40-PtRh20,

W-WRe26, WRe5-WRe26, PlatinelII, NiMo-

Ni,CR-AuFe, U, L

Resistance thermometer --- Pt100, JPt100, Pt50, Pt-Co

*Contact CHINO for Nickel-100, Pt130, Pt25, Pt46, Cu10,Cu25,Cu53

 

Accuracy ratings:   ±0.1%±1 digit for DC voltage input

                    

 

Reference junction compensation accuracy:

K, E, J, T, N, PlatinelII --- ±0.5°C or less

R, S, W-WRe26, WRe5-WRe26, NiMo-Ni, CR-AuFe, U, L --- ±1.0°C or less

 

Sampling rate:

Approximately 1sec./ 48 points

Disconnection of input signal is detected on thermocouple and resistance thermometer input. UP/DOWN/DISABLE is selectable.

 

Scaling:

Range/scale is selectable.

 

Digital filter:

Programming FIR filter for each point (common to

all points)

 

Allowable signal source resistance:

Thermocouple input (burnout disabled)/

DC voltage input (±2V or less) ---1kΩ or less

DC voltage input (±5V or more) ---100Ω or less Resistance thermometer --- 10Ω or less per wire (same resistance for 3 wires should be the same)

 

 

Input resistance:

Thermocouple input, DC voltage input --- Approx. 1 MΩ

 

Maximum input voltage:

DC voltage input (±2V or less)

Thermocouple DC voltage input (burnout disabled) --- ±10VDC DC voltage input (±5V to ±50V) --- ±60VDC

 

Dielectric strength between channels:

1000V AC or more between each channels

(High strength semiconductor relay used)

(B terminal of resistance thermometer is shorted inside between channels)

 

Common mode rejection ratio:

120dB or more

 

Series mode rejection ratio:

50dB or more

 

RECORDING SPECIFICATIONS

Additional memory:

CF card (Up to 8GB)

USB memory (Up to 8GB)

 

Recording cycle:

1, 2, 3, 5, 10, 15, 20, 30s,

1, 2, 3, 5, 10, 15, 20, 30, 60min

 

Logging data:

Measured data --- File name (group name), time of day, month and year of recording start, tag, measured data, alarm status/types and marker text

Setting parameter --- All parameters

Operation result data

 

Storing types:

Binary/CSV, selectable

 

Storing methods:

Manual start/stop (dedicated touch key operation)

Schedule (designation for time of day and date)

Trigger signal (alarm event, digital input)

Data recording of before and after trigger

*Pre-trigger is selectable.

Measuring numbers of pre-trigger --- Maximum 950 data

 

 

Recording group:

Up to 6 groups of 56 points can be programmed

(Up to total of 128 points)

 

COMPUTATION SPECIFICATIONS

Computation points:

Up to 128 points

 

Computation cycle:

100ms/ all every points

 

Computation types:

Arithmetic operations ---

Addition, subtraction, multiplication, division, remainder, exponential

Comparison operations ---

Equality, inequality, great, less, equality/great, equality/less

 

Logical operations ---

AND, OR, XOR, NOT

 

General functions ---

Round-up, round-down, absolute value, square root,

Exponent of e, natural logarithm, common logarithm

Integration operations ---

Analog integration, digital integration

Channel data operations ---

Measured data computation,

Calculated data computation

 

Others ---

Dew point, relative humidity, F-value Remaining capacity of CF card moving average

Wind direction (displays16 directions)

 

ALARM SPECIFICATIONS

Setups:

Up to 4 alarms can be programmed per channel

 

Alarm types:

Upper limit, lower limit, differential upper limit, differential lower limit (deadband is selectable), abnormal data

 

Delay function:

Setup range of alarm delay --- 0 to 3600sec.

 

Alarm settings:

AND/OR selectable

 

Alarm outputs:

Refer to optional specifications

 

DISPLAY SPECIFICATIONS

Display:

10.4"VGA TFT color LCD

 

Display types:

Measured data display (Trend screen, Data screen, Bar-graph screen, Circular trend screen)

Historical trend display (simultaneous display with Real-time trend is available)

Information display (alarm display, marker list, file list)

Setting screen (alarm, computation, memory, system, maintenance, communication, etc.)

 

Trend screen:

48 colors selectable

Display screen group--- Up to 6 groups

Display points --- Up to 56 points/group

Time axis direction --- Vertical, horizontal or circular

Line width --- selectable from 5 kinds

Scale display --- 4 scales

Tag/data display --- Show/hide selectable

Marker display

 

Numeric Data Display:

Display group--- Up to 6 groups

Display points --- Maximum 56 points/group

Display contents --- Measured value, channel/tag, unit, alarm status

 

Bar-graph screen:

48 colors selectable

Display screen group --- Up to 5 groups

Display points --- Maximum 56 points/group

Display direction --- Vertical or horizontal

Scale display --- 1 scale

 

Information display:

Alarm display (alarm activation/released history display) Marker list

File list (file list display of group data file)

Unit information (Model, Serial No, Option, etc.)

 

LCD back light:

Auto/manual OFF function

Brightness --- 4 levels adjust table

 

COMMUNICATION  FUNCTIONS

• Network (Option)

 

Communications type:

Ethernet (10BASE-T/100BASE-TX)

 

FTP server:

Data file can be read from the network computer

 

FTP client:

Transfer a data file to a network server

 

SNTP client:

The time can be synchronized to the time of SNTP server

 

Web server: 

Conformed to HTTP1.0 --- Displays screens, the alarm and information of maintenance by browser software (Internet Explorer 5.0 or later)

* User's ID and password registration available

 

E-Mail:

E-Mail notification at specified time for alarm activation Report data at specified time is selectable from all registered data

Notification address --- Maximum 8

 

 

• USB Communications

 

USB:

Communication type --- USB1.1

Transfer systems --- Bulk transfer, control transfer

File transfer by connecting as removable disk drive

 

OPTION SPECIFICATIONS

Alarm output:

Mechanical relay (c contact) output for alarm activation and input error.

Output point: 4 or 2 points

Contact capacity: resistive load 3A, inductive load 1.5A

 

Digital input (Non-voltage contact input/ 4 or 2 points):

ON/OFF signal: ON/OFF input recording

Pulse input: Maximum 10Hz pulse input

Used for flow rate, operation time and frequency

External drive: The following operations are available (selectable by parameter)

. Data memory triggering

. Marker display

. Integrated calculation reset

 

Communications interface:

High and low-order communication: Communications interface for high and low-order unit

RS485 (MODBUS)

Choose one function from the following 3 functions.

. Communication interface for high-order unit. Recording input data of CHINO products connected to a low-order unit and data in

PLC register.

Display and record parameter setting, measured value, setting value, etc. of up to 16 CHINO controllers.

Recording points:

12-channel specification --- 108 points 24-channel specification --- 96 points 36-channel specification --- 84 points 48-channel specification --- 72 points

Connectable models: KE, KR2S, KR3S, KR2000, KR3000,

LE5000, AL3000, AH3000,

DB1000, 2000, LT230, 830, 350, 370, 450, 470,

KP1000, KP2000, DP-G

(data collection only) JU, JW, SE3000

. Transfer input data of KR3S to PLC.

The input data can be written on PLC only. Data writing points: 44 points

Connectable PLC: Mitsubishi Electric Corporation

MELSEC AnA, QnA, QnAS, FX series OMRON Corporation SYSMAC series

Note) Separate purchase of protocol converter SC8-10 (optional) is required for connection to OMRON PLC.

 

 

Others:

Handle and rubber feet

 

 

GENERAL SPECIFICATIONS

Rated power voltage:

100 to 240V AC (universal power supply) 50/60Hz

 

Maximum power consumption:

60VA

 

Reference operating condition:

Ambient temperature --- 21 to 25°C

Ambient humidity --- 45 to 65%RH

Power voltage --- 100V AC±1.0%

Power frequency --- 50/60Hz±0.5%

Attitude --- Left/right, forward 0°, backward 0° Warm-up time --- Longer than 30 minutes

 

Normal operating condition:

Ambient temperature --- 0 to 50°C

Ambient humidity --- 20 to 80%RH

Power voltage --- 90 to 264V AC

Power frequency --- 50/60HZ ±2%

Attitude --- Left/right, forward 0°, backward 0° to 20°

 

Transport condition (at the packed condition on shipment from our factory):

Ambient temperature --- -20 to 60°C

Ambient humidity --- 5 to 90%RH (No dew condensation) Vibration --- 10 to 60Hz, 4.9m/s2 (0.5G) or less

Impact --- 392m/s2 (40G) or less

 

 

Storage condition:

Ambient temperature --- -20 to 60°C

Ambient humidity --- 5 to 90%RH (No dew condensation)

 

Power failure protection:

Flash memory stores the settings and the data.

Lithium battery backs up the clock and parameter RAM for more than 5 years (provided that the daily operating hours is longer than 8 hours).

 

Insulation resistance:

Secondary terminals and protective conductor terminals --- 20MΩ or more at 500V DC

Primary terminals and protective conductor terminals --- 20MΩ or more at 500V DC

Primary and secondary terminals --- 20MΩ or more at 500V DC

Primary terminals: power terminals (L, N), alarm output terminals Secondary terminals: measuring input terminals, digital input terminals, communications terminals

 

Dielectric strength:

Secondary terminals and protective conductor terminals --- 1 minute at 500V AC

Primary terminals and protective conductor terminals ---

1 minute at 1500V AC

Primary and secondary terminals --- 1 minute at 2300V AC Primary terminals: power terminals (L, N), alarm output terminals Secondary terminals: measuring input terminals, digital input terminals, communication terminals

 

Case assembly material:

Front bezel --- Polycarbonate and ABS resin (frame)

Case --- Steel

 

Color:

Front bezel --- Black (equivalent to Munsell N3.0)

Case --- Gray (equivalent to Munsell N7.0)

 

Weight:

Approximately 5.6kg (at maximum)

 

 

Mounting:

Panel mounting

 

Terminal screws:

Power terminals/protective conductor terminals --- M4.0 Measuring input terminals/alarm output terminals/digital input terminals --- M3.5

Communications terminals --- M3.0

 

Performance Specification Sheet Paperless Recorder Series KR3S Series Download
Leave a feedback