Thermal Imaging
CPA-R Relay Lens Type Furnace Monitoring Camera
This system utilizes a CCD camera, which has sensitivity at 1.0µm and Image Processing Unit that provides an image and converts video signal from the camera into temperature information. The special high temperature optics lens array system can be inserted through a small insertion port on many types of furnaces. The Image Processing Unit has an 8.3” LCD touch panel that displays wide-angle image and temperature information. It also provides the capability of up to 40 points of Contact Inputs/Outputs as well as 32 points of Analog Outputs through an external I/O unit.

Download Application check sheet
CPA-R SeriesCPA-R Series
CHINO Corp. India Pvt. Ltd. - Thermal Imaging - TP-L Thermal Imaging Sensor
    Temperature Measurement Type and Video Monitoring Type are available
    Protective tube 360, 500, 680, 900 and 1100mm length for various application
    Retracting system for safety (Accessory)
    Water+Air Cooling for high temperature application
    Model Lens Type Cooling System Monitoring System
    CPA-R00S⬚⬚-WNN 100°Lens Water & Air Cooling Temperature Measurement Type
    CPA-R60S⬚⬚-WNN 60°Lens
    CPA-R45S⬚⬚-WNN 45°Lens
    CPA-R00S⬚⬚-ANN 100°Lens Air Cooling Only Temperature Measurement Type
    CPA-R60S⬚⬚-ANN 60°Lens
    CPA-R45S⬚⬚-ANN 45°Lens
    CPA-R00S⬚⬚-WNC 100°Lens Water & Air Cooling Video Monitoring Type
    Temperature measurement is not available
    CPA-R60S⬚⬚-WNC 60°Lens
    CPA-R45S⬚⬚-WNC 45°Lens
    CPA-R00S⬚⬚-ANC 100°Lens Air Cooling Only Video Monitoring Type
    Temperature measurement is not available
    CPA-R60S⬚⬚-ANC 60°Lens
    CPA-R45S⬚⬚-ANC 45°Lens
    ⬚⬚: Array Length
    04: 360mm
    05: 500mm
    07: 680mm
    09: 900mm
    11: 1100mm
    Model Description
    CPG-GMPR Image Processing Unit
    CCZ-ZRP Camera Power Supply Box
    CPY-ZRC⬚⬚ (5m, 10m and 25m are available) Custom Cable
    CPY-ZRB⬚ (1, 2 or 3) Video Input Cable
    CPY-ZRX Video Input Box
    Retracting System
    Lens Array and Camera Unit
    Viewable Angle H96" x V70" (100º Lens)
    Wavelength 0.8 to 1.0µm
    Temp Range 700º to 2500ºC (Assignable Span:200º to 500ºC)
    Monitoring Method Standard - Monitoring on Output - Provides Analog Color signal
    Accuracy ±1% at Full Scale (Black Body)
    Image Processing Unit
    Camera Control Up to 3 Cameras
    Display 8.4" Color LCD (Touch Panel)
    External Input/Output Contact Output: Max 40 points (w/ Optional I/O unit)
    Contact Input: Max 40 points (w/ Optional I/O unit)
    Analog Outpu: Max 32 points (w/ Optional I/O unit)
    Analyzing Function Spot: 16 spots
    Line: 32 lines
    Area: 32 areas
    Filter: Binalize/Pixel/Edge
    Operational Condition Temperature: 0 to 45°C
    Humidity: 20 to 85%RH (Non Condensation)
    Protective Structure IP65 Compliant (Front Panel)
    External I/O Unit (Optional)
    AC/DC Power Supply Unit 100 - 120V AC
    I/O Controller Module For connecting Processing Unit and I/O Module
    Digital I/O Module 8 In/8 Out per Module, Up to 4 Modules
    Analog Output Module 4 Outs per Module, Up to 8 Modules
    Example
    CPY-ZFP011 - Display/Setup Software (offline use)
    This software is to display thermal image data that has been saved on the processing unit. The data can be transferred from the processing unit via USB memory stick. The interface and appearance on the display are the same as the processing unit, therefore you can also change/manage Settings File and System Setup.
    CPY-ZFP002 - Data Logging/Analysing Software
    This package software is to support large amount of data logging and analysis via LAN connection.
    PS Sheet CPA-R series Monitor Type Specification Download
    PS Sheet CPA-R series Temperature Measurement Specification Download
    PS Sheet CPA-R series Stoker Furnace Application Note Download
© 2014 CHINO Corp. India Pvt. Ltd.