KR2000/3000 Series Graphic Recorder
with measured data protection

KR2000/3000 series are paperless recorders that prevent falsification of data to meet the requirements of FDA 21CFR Part11 for medicinal chemical manufacturing. Employs high visibility display and high operating function. Also it realize data recording and management easy operation.
* FDA 21CFR Part11: The U.S. Food and Drug Administration rule on electronic records and electronic signatures. It is a requirement when replacing the paper-based records to electronic media and enacted in 1997.

Standard KR2000 Series Graphic Recorder
Standard KR3000 Series Graphic Recorder

KR3000 Series
TabView Example - Basic From Existing Markup
    Easy Operation
    Touch screen (KR3000)
    High speed smapling 100ms
    Export data to USB flash drive
    LAN network capability
    Various functions such as calculation
    Model Measuring points/sampling rate
    KR2P60MN0A 6points/100ms
    KR2P20MN0A 12points/100ms
    KR2P61MN0A 6points/1s
    KR2P21MN0A 12points/1s
    Model Measuring points/sampling rate
    KR3P20-N0A 12points/100ms
    KR3P40-N0A 24points/100ms
    KR3P60-N0A 36points/100ms
    KR3P80-N0A 48points/100ms
    KR3P21-N0A 12points/1s
    KR3P41-N0A 24points/1s
    KR3P61-N0A 36points/1s
    KR3P81-N0A 48points/1s
    INPUT SPECIFICATIONS
    Measuring points KR2000---6 points, 12 points
    KR3000---12 points, 24 points, 36 points and 48 points
    Input types Universal
    DC voltage: ±13.8mV, ±27.6mV, ±69.0mV, ±200mV, ±500mV, ±2V, ±5V*, ±10V*, ±20V*, ±50V*
    (*with built-in voltage divider)
    DC current: With external shunt resistor (sold separately)
    Thermocouple: B, R, S, K, E, J, T, N, PtRh40-PtRh20, W-WRe26, WRe5-WRe26, PlatinelⅡ, NiMo-Ni, CR-AuFe, U, L
    Resistance thermometer: Pt100, JPt100, Pt50, Pt-Co
    Accuracy ratings 0.1% digit (exceptions)*Measurement range conversion accuracy
    Reference junction compensation accuracy K, E, J, T, N, PlatinelⅡ--- ±0.5ºC or less
    R, S, W-WRe26, WRe5-WRe26, NiMo-Ni, CR-AuFe, U, L --- ±1.0 ºC or less
    Sampling rate 100ms: Approximately 100ms for all points
    1s: Approximately 300ms for all points
    Burnout Disconnection of input signal is detected on thermocouple and resistance thermometer input. UP/DOWN/DISABLE is selectable for each input
    *When sampling rate is set below 0.5s at KR2P61/ KR2P21, then input will automatically becomes 4 points and sampling rate will be 100ms.
    RECORDING SPECIFICATIONS
    Internal memory 512MB
    Exterior memory Store the data file to USB flash drive
    Recording cycle 100, 200, 500ms
    1, 2, 3, 5, 10, 15, 20, 30s
    1, 2, 3, 5, 10, 15, 20, 30, 60min
    Logging data

    Measured data --- Time of day, month and year of recording start, tag, measured data, alarm status/types, makertext, etc
    Setting parameter--- All setting parameter
    Computation result data

    Storing types Binary type
    Storing methods Manual start/stop
    Schedule (designation for time of day and date)
    Trigger signal (alarm event, digital input)Data logging of before and after trigger points
    * Pre-trigger is selectableMeasuring numbers of pre-trigger --- Max 950 data
    COMPUTATION SPECIFICATIONS
    Computation points KR2000---Max 44 points
    KR3000---Max 128points
    Computation types Arithmetic operation, comparison operations, logical operations, integration operations, channel data operations, dew point, relative humidity, wind direction, 16 direction display, increment per time, remaining amount of internal memory, abnormality judgment, user lockout judgment
    DISPLAY SPECIFICATIONS
    Display types Measured data display
    (Trend screen, Data screen, Bar-graph screen)
    Historical trend display(simultaneous display with Real-time trend is available)
    Information display(alarm display, marker list, file list)
    Setting screen(alarm, computation, memory, system, maintenance, communication, etc.)
    Display points KR2000---Max 44 points
    KR3000---Max 128points
    *The LCD display may contain some pixels that always or never illuminate, and the brightness of some areas of the display may appear uneven. These are typical LCD performance characteristics and don no constitute malfunctions.
    COMMUNICATION FUNCTIONS
    Communication type Ethernet (10BASE-T/100BASE-TX)
    FTP client Transfer a data file to a network server
    SNTP client The time can be synchronized to the time of SNTP server
    E-Mail E-Mail notification at specified time for alarm activation
    Report data at specified time is selectable from all registered dataNotification address --- Maximum 8 contacts
    ALARM SPECIFICATIONS
    Setups Up to 4 alarms can be programmed per channel
    Alarm types Upper limit, lower limit, differential upper limit, differential lower limit (deadband is selectable), abnormal data
    Delay function Setup range of alarm delay---0 to 3600 seconds
    Alarm settings AND/ OR selectable
    GENERAL SPECIFICATIONS
    Rated power voltage 100 to 240V AC (universal power supply) 50/60Hz
    Maximum power consumption KR2000---50VA
    KR3000---65VA
    Normal operating condition Ambient temperature --- 0 to 50ºC
    Ambient humidity --- 20 to 80%RH
    Power voltage --- 90 to 264V AC
    Power frequency --- 50/60Hz±2%
    Attitude --- left/right 0°, forward tilting 0°,
    backward tilting 0° to 20°
    Weight KR2000---About 2.2kg (max)
    KR3000---About 7.2kg (max)
    Mounting Panel mounting
    STANDARDS
    Protection KR2000---IEC529 IP65 compliance (front part)
    KR3000---IEC529 IP54 compliance (front part)
    CE KR2000 (approved)
    KR3000 (approved)
    EMS directive---
    EN61326-1 Class A
    EN61000-3-2
    EN61000-3-3
    Low voltage directive---EN61010-1
    Over voltage (installation) category II, pollutionlevell 2, measuring category II
    *The indication equivalent to 1mV may vary under the test environment by EMS directives.
    OPTION SPECIFICATIONS
    Please see standard version's PS sheets.
    Real-time trend screen
    KR3000
    Real-time trend screen
    KR2000
    Preventing Falsification of Data
    Store the file in binary format. Display a message if falsified.

    Binary file example
    Audit Trail
    Electronic signature to electronic file. Display audit operation.

    Audit trail screen & File information display
    Login Function
    Register up to 5 administrators and 100 general users and only registered users can access.
    Set 10 kinds of access authority and signature level.

    Smooth Operation by Touch Screen!!
    Input/Computation setting & Login operation.

    PS Sheet KR2000/3000 Series
    with measured data protection
    PSE-365 Download
    Instruction Manual KR2000/3000 Series
    with measured data protection
    INE- Download